MAX POWER SERVICES
+91 9382836363 ,+91 9380802260
WHY SHOP WITH US?
Delivery On Time
Professional Installation
Best Prices

PORTABLE - 3.0kVA

Genset Model
KCC-P-3.0AS
Rated Output at rated rpm
kW
3
Frequency
Hz
50
Maximum Output
kW
3.3
Rated Current
A
8.34
Voltage
V
230 ,Single Phase AVR Type
Governing class ( As per ISO 8528 Part-V)
G2
Sound Power Level LWA
dBA
< 86
Noise level ( 1M) For reference
dBA
71
Fuel Consumption* At 100 % Load
Ltrs/Hr
2.1
At 75 % Load
1.7
At 50 % Load
1.3
Fuel Tank Capacity
Ltrs
12.5
Overall dimensions of genset (L x W x H)^

mm
1045×550×735
Weight of genset with canopy (approx..)^
Kg
129
ENGINE
Engine Model
CCP302
Rated output (Prime Continuous rating as per ISO 3046)
kW
4.2
HP
5.7
No. of cylinder
Number
1
Cubic capacity
CC
302
Rated Speed
RPM
3000
Bore & Stroke
 
80x60
Compression Ration
 
8.3(±1):1
Cooling System
 
Air Cooled
Ignition System
 
TCI
Type
 
4 Stroke OHV
Spark Plug
 
MICO Super
Starting System
 
Electric / Recoil Start
Aspiration
NA/TC/TA
NA
Lube Oil change period
hrs.
100
Lube oil Sump Capacity
Ltrs
1.1
ALTERNATOR
Insulation Class
Class H
Alternator Efficiency (at 100% load) 0.8 pf**
%
74
Max Voltage Dip at Full Load 0.8 pf Lag
sec
< 20 %
Max Time to build up rated voltage at Rated RPM < 5 sec provided engine reach the rated speed
BATTERY
Electricity battery starting voltage
12
FEATURES
Oil Alert, Circuit Breaker, Volt Meter, Hour Meter, Pilot Lamp & Rcoil Start

For intermediate ratings, kindly contact nearest KOEL office
Notes ^ Tolerances Apply *With 0.845 Specific Gravity of diesel ( 5 % Tolerance )

** Efficiency of Alternator as per standards IS 4722 and IEC 34-1 For Site Conditions other than standard operating conditions consult KOEL for available prime power.

Prime rating and Stand‐by rating1

‘Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rating to meet their requirement. KOEL offers Prime power as standard offer. Contact KOEL for stand-by ratings.

Engine capacity does matter2

Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.

Higher engine capacity also enables Genset to respond quickly & positively to sudden load additions.


1. Canopy
  • Ease of Access and Serviceability
  • Aesthetically designed, weather and sound resistant enclosure
  • Insulation conforms to UL94-HF1 class for flammability

  • 2. Controller
  • Microprocessor based fully configured
  • Graphical bigger LCD display
  • Best in class monitoring and diagnostic
  • Integrable with AMF

  • 3. Engine
  • O2E Series: Low emission, high efficiency engines
  • Compact, Robust and Rugged Design
  • 500 hours lube-oil change period

  • 4. Alternator
  • Best In Class Efficiency
  • Special Windings to Reduce Harmonics
  • Vacuum Pressure Impregnation and epoxy gel coating on winding
  • Monitoring Features
  • Lube oil Pressure, Engine Temperature, RPM, lube oil Temperature*
  • Run Hours, No. of starts, Fuel Level, Auto / Manual Stop, Battery charge condition, AC Phase Voltage, Current, kVA, KW, KVAr, KWH, Power Factor
  • Optional Features
  • Modbus communication* (Features are available from 15 kVA onwards)
  • Diagnostic Features
  • Battery charging failure, Over speed, Under speed, Over Current, Under Voltage, Over Voltage, Over KW, Phase Sequence monitoring, Phase missing, Common Alarm, Hooter output
  • Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level alarm, Over Crank protection, Routine Maintenance indicator, Genset Test Facility, fail to start/stop
  • Being in control of your Genset is certainly a winning edge!