Engine
O2E Series: Low emission, high efficiency engines. Compact, Robust and Rugged Design 500 hours lube-oil change period. Integral set - mounted radiator system, designed & tested for 50oC ambient temperature.
+91 9382836363 ,+91 9380802260
SPECIFICATIONS | ||||||
---|---|---|---|---|---|---|
Prime Ratingat rated rpm (as per ISO 8528) | kVA | 750 HD | 900 HD | 1010 HD | 1250 HD | 1500 HD |
kW | 600 | 720 | 808 | 1000 | 1200 | |
Genset Model | KG1-750WS | KG1-900WS | KG1-1010WS | KG1-1250WS | KG1-1500WS | |
Frequency | Hz | 50 | ||||
Power factor | lagging | 0.8 | ||||
Voltage | V | 415(30) | ||||
Governing class (As per ISO 8528 Part-V) | G3 | |||||
DG set Noise level at 1 meter | dBA | <= 75 | Contact Kirloskar oil engine ltd. for details | |||
Fuel Consumption‘* (At 100% load) | Ltrs/hr | 154 | 197 | 199 | 250 | 310 |
Fuel Consumption‘* (At 75% load) | Ltrs/hr | 126.4 | 163 | 155 | 189 | 230 |
Fuel Consumption‘* (At 50% load) | Ltrs/hr | 89.7 | 120 | 112 | 134 | 157 |
Fuel tank capacity (Standard DG set) | Ltrs | 990 | 990 | 990 | 880 | 880 |
Weight of genset with Canopy approx^ (Dry) | Kg | 8300 | 13600 | 13200 | 13075+ | |
Overall dimensions of Genset^ (Length) | mm | 6800 | 8000 | 7800 | 5650+ | |
Overall dimensions of Genset^ (Width) | mm | 2300 | 2300 | 2300 | 2300+ | |
Overall dimensions of Genset^ (Height) | mm | 2713 | 2713 | 2713 | 2680+ | |
Electrical Battery starting voltage | Volts-DC | 24 | ||||
ENGINE | ||||||
Engine Model | DV12ETA | DV16ETA | DV16ETA | 12K4300 - E2 | 12K4300 - E1 | |
Rated output (Prime continuous rating as per ISO 3046) | kW | 663 | 799 | 899 | 1090 | 1294 |
HP | 991 | 1066 | 1210 | 1482 | 1760 | |
No. of Cylinders | Number | 12 | 16 | 16 | 12 | 12 |
Cubic capacity2 | Ltrs | 23.88 | 31.84 | 31.84 | 51.73 | 51.73 |
Bore x Stroke | mm | 130 x 150 | 170 x 190 | |||
Rated Speed | RPM | 1500 | ||||
Aspiration | NA/TC/TA | TA | ||||
Lube Oil change period | hrs. | 500 hrs. | ||||
Lube oil Sump Capacity | Ltrs | 73 | 130 | 130 | 265 | |
Coolant Capacity | Ltrs | 175 | 180 | 80 | 210 | |
ALTERNATOR | ||||||
Insulation Class | Class H | |||||
Alternator Efficiency (at 100% load) 0.8 pt** | % | 94.6 | 95.3 | 95.1 | 95.7 | 95.4 |
Alternator Efficiency (at 75% load) 0.8 pt** | % | 94.9 | 95.5 | 95.4 | 95.9 | 95.8 |
Permissible Voltage Dip at Full Load 0.8 pf Lag | % | <20% | ||||
Time permitted to build up rated voltage at Rated RPM | <1 sec provided engine reach the rated speed | |||||
Short circuit withstand time | sec | 3 Times rated current for "10 sec" | ||||
Overload withstand capacity | % | 10% overload for one hour once in 12 hour |
Notes:
^ Tolerance Apply
# with 0.845 specific gravity of diesel (5% tolerane).
$ These Weight are for handling & transportation only
* Efficiency of Alternator as per standards IEC60034-1
+ weight & dimension are for open genset for canopised genset,please contat kirloskar
oil engine Ltd
For intermediate ratings, kindly contact nearest Kirloskar office
For Site Conditions other than standard operating conditions consult
Kirloskar Oil Engines for available prime power.
Kirloskar iGreen gensetsare enabled with Kirloskar remote monitoring system which shares Real nme Genset information and location Services. It can be accessed via mobiledevice or desktop.
O2E Series: Low emission, high efficiency engines. Compact, Robust and Rugged Design 500 hours lube-oil change period. Integral set - mounted radiator system, designed & tested for 50oC ambient temperature.
Microprocessor based with graphical LCD display. Best in class monitoring and diagnostic capability. Communication configuration enabled.
Ease of Access and Serviceability . Aesthetically designed, weather and . sound resistant enclosure. Insulation conforms to UL94-HF1 class for flammability.
Best in class efficiency. Mltienrimnautmohrarmonics interference diagnostic capability. Communication configuration enabled. Vacuum pressure impregnation. Epoxy gel coating on the winding.
‘Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rating to meet their requirement. Kirloskar offers Prime power as a standard offer. Contact Kirloskarfor stand-by ratings.
Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance. Higher engine capacity also enables the Genset to respond quickly & positively to sudden load additions.
Kirloskar Gensets offer a unique combination of CPCB norm compliance and enhanced fuel efficiency. Across the range, Kirloskar Gensets offer substantial savings in fuel cost. O2E Series (Optimal Operating Efffciency): Genset ratings are selected based on the present load and future expansion. Fuel efficiency of most Gensets is optimized at the full rating of the Genset. In practice, Gensets rarely get loaded to full capacity. Power demand variations across day & night, weekdays & weekends, summer & winter lead to an average 50-70% loading on Gensets. Considering this practical situation, Kirloskar has extended fuel efficiency optimization from 100%, right up to 50% of rated load. In line with fuel efficiency Kirloskar Genset ensures the better DEF efficiency and accordingly optimized the DEF tank size. Combination of best-in-class fuel efficiency & O2E provides a double advantage.
Common rail diesel injection technology, popularly known as CRDi, provides a significant upgrade over traditional mechanical fuel injection systems. CRDI provides precise fuel control, multiple injections, enhanced performance, lower noise and reduced emissions. High pressure common rail system employed on Kirloskar CPCB IV+ Gensets maximizes fuel atomization, delivering a smooth and smoke free performance. Diesel filters with ‘A’ class filtration are used for CRDi Engines which enhances the filtration efficiency. Common rail fuel injection system will provide a new level of performance, efficiency, and reliability.
Kirloskar gensets are enabled with Kirloskar remote monitoring system which shares Real Time Genset information and location Services. It can be accessed via mobile device or desktop. Kirloskar remote monitoring system also highlights any parameter which needs special attention. These critical indication alerts are sent to user mobile via text message. It also alerts nearest services dealer in case of any emergency break-down.
Superior uptime. Genset comes with advanced diagnostic capabilities, this coupled with Kirloskar remote monitoring system provides real time monitoring of performance, emission and service critical parameters this helps for early diagnosis to fix the issues before system breakdown
Kirloskar Genset put the command in your hands. Micro-processor based Genset
controllers display a host of genset parameters and put all controls at your
fingertips.
Monitoring Features:
Phase Voltages & Currents, Frequency, Genset kVA, kW, kWh, kVAr, Power Factor
Lube oil Pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel
Level, Auto / Manual Stop, Battery charge condition, AMF feature
Diagnostic Features:
Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over
kW, Phase Seq., Phase missing, Mains Under voltage, Low fuel level
Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel
Level, Over Crank protection, Routine maintenance indicator, Genset Test Facility,
Mains Frequency
Optional Features:
Modbus Communication, Synchronization
Kirloskar Gensets have always been preferred for their robust design and reliability over long usage life. Kirloskar range carries the confidence of well-established and proven engine platforms. For compliance to revised CPCB norms, Kirloskar has carefully selected those technologies which not only retain, but enhance Gensets durability and on-site serviceability. Thus, Kirloskar Gensets offer you many years of trouble-free performance; backed by the assurance of prompt support. Peace-of-mind driven by product reliability and low cost of ownership.
Kirloskar Alternator is compact in design, rugged and best in class efficiency. Advanced Digital AVR improves the Voltage regulation and Response time.
Kirloskar CPCB compliant Gensets are having compact footprint which results in space saving. CPCB compliant technology is upgraded by maintaining the compact footprint of Genset.
India's first loT enabled digital genset. Designed for convenient user experience. Best-in-class fuel efficiency delivered. Compact design & long life product. Optimized consumption of lubricant oil. Optimized total cost of ownership (TCO). All products tested before delivery.
Load sizing for every single genset order. One stop power back-up solutions. Serves complete application gamut. Highly trained & experienced team. Non-conventional solutions (bio-diesel). Specific solution for harsh environments. Exhaust mgmt., foundation, cabling etc.
India's widest service dealer network. Kirloskar connect-sett-service application. eFSR-Electronic field service report. Over 6000 trained service engineers. Over 600,000 machines under care. 98%+ parts available at each outlet. Flexible & economical AMC-Bandhan.
Consistent, reliable & long-established. 250+ expert touch points across India. 500+ solution oriented professionals. Uniform customer experience across. Central system for enquiry to PRF. Fair trade practices & Price transparency.
Cost-effective deliveries guaranteed. Assured 7-day delivery of gensets. Supports project management system. Reduced working capital for customer. Award-winning replenishment model. Assurance of FRESH products always.
24 X 7 operational customer care centre. Team of over 70 trained & focused exec. Tracking every service request till closure. Centrally maintained CRM for all requests. Satisfaction call after every SR closure. Central sales lead tracking system. Continuous NPS and CDI measuremen.
Why get satisfied with power back-up 4 digit & 4 fans