PORTABLE - 5kVA
Prime Rating at rated rpm ( as per ISO8528) |
kVA |
5
|
|
kW
|
4 |
||
Product Name |
KP5000 |
||
Genset Model |
KCC-P-4.0 AS |
||
Rated output at rated rpm |
kW |
4 |
|
Maximum Output |
kVA |
5 |
|
Rated Current |
A |
17.4 |
|
Frequency |
Hz |
50 |
|
Voltage |
V |
230, Single Phase AVR Type |
|
Govering (As per ISO 8528 Part-V class) |
G2 |
||
Sound Power Level LWA | dBA |
≤ 86 |
|
Noise Level (1M) – for Reference | dBA |
71 |
|
Noise level |
dBA |
< 75 |
|
Fuel Consumption* | At 100 % Load |
Ltrs/Hr |
3.3 |
At 75 % Load |
2.6 |
||
At 50 % Load |
2.0 |
||
Fuel Tank Capacity |
Ltrs |
12.5 |
|
Overall dimensions of genset (L x W x H)^ |
mm |
1045 x
550 x
735 |
|
Dry weight of genset with canopy (approx..)^ |
Kg |
145 |
|
ENGINE | |||
Engine Model |
|
CCP389 |
|
Rated output (prime continuous rating As per ISO 3046) |
kW |
5.6 |
|
HP |
7.6 |
||
No. of cylinder |
Number |
1 |
|
Cubic capacity |
cc |
389 |
|
Bore x Stroke |
mm |
88X64 |
|
Compression Ratio |
8.3(± 1):1 |
||
Cooling System |
Air Cooled |
||
Ignition System |
TCI |
||
Type |
4 Stroke OHV |
||
Spark Plug |
MICO Super |
||
Starting System |
Electric/ Recoil Start |
||
Lub oil changed period * |
hr |
100 |
|
Lub oil sump capacity |
Lit |
1.1 |
|
ALTERNATOR | |||
Insulation Class |
|
Class H |
|
Alternator Efficiency (100%) |
|
74% |
|
Max Voltage Dip at Full Load 0.8 pf lag |
|
≤ 20% |
|
Max Time to build up rated voltage at Rated RPM |
|
< 5 sec provided engine reach the rated speed |
|
BATTERY | |||
Electric Battery Starting Voltage |
|
12 |
|
FEATURES | |||
Oil Alert, Circuit Breaker, Volt Meter, Hour Meter, Pilot lamp & Recoil Start |
|
|
For intermediate ratings, kindly contact nearest KOEL office
Notes
^ Tolerances Apply
*With 0.845 Specific Gravity of diesel ( 5 % Tolerance )
** Efficiency of Alternator as per standards IS 4722 and IEC 34-1 For Site Conditions other than standard operating conditions consult KOEL for available prime power.
‘Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rating to meet their requirement. KOEL offers Prime power as standard offer. Contact KOEL for stand-by ratings.
Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.
Higher engine capacity also enables Genset to respond quickly & positively to sudden load additions.

1. Canopy
2. Controller
3. Engine
4. Alternator